Spectrophotometer

  Jenway Spectrophotometers

Jenway offers its full range of spectrophotometers to suit all budgets and applications requirements, as shown in the table below the product listings. To obtain additional information of each Jenway Spectrophotometer and specification details, please select the appropriate product.

Jenway Spectrophotometer Brochure 

Selecting a Jenway Spectrophotometer
Jenway Model Visible UV Scanning Single beam Split beam Double beam Micro-volume Bandwidth
6300 + - - + - - - 8nm
6320D + - - + - - - 8nm
6305 + + - + - - - 8nm
7200 + - + + - - - 7nm
7205 + + + + - - - 5nm
7300 + - - + - - - 5nm
7305 + + - + - - - 5nm
7310 + - + + - - - 5nm
7315 + + + + - - - 5nm
7410 + - + + - - - 5nm
7415 + + + + - - - 5nm
6700 + - + - + - - 4nm
6705 + + + - + - - 4nm
6715 + + + - + - - 1.5nm
6850 + + + - - + - 0.5, 1, 2, 4, 5nm
Genova Bio + + + + - - - 3nm
Genova Plus + + + + - - - 5nm
Genova Nano + + + + - - + 5nm
7415 Nano + + + + - - + 5nm

 

Use the search box to narrow the results of your search. RESET to clear your search. 

SKU# 6300

Visible spectrophotometer supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, interface cable and PC application software on CD-ROM*

• Wavelength range of 320 to 1000nm
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessories


The 6300 high quality, low cost unit for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries.
 
Technical Specification

Parameter Jenway 6300 Spectrophotometer
Wavelength range 320 to 1000nm
Wavelength resolution 1nm
Wavelength accuracy ±2nm
Spectral bandwidth 8nm
Transmittance 0 to 199.9%T
Absorbance –0.300 to 1.999A
Accuracy ±1%T
Resolution 0.1%T, 0.001A
Stray light <0.5%T
Noise <1%
Stability 1%/h after 15 minutes
Concentration range –300 to 1999
Concentration resolution 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999
Light source Tungsten halogen lamp
Outputs Analogue and RS232
Power <50W
Size (w x d x h) 365 x 272 x 160mm
Weight 6kg
 

 

Availability: IN STOCK
SKU# 6320D

Visible spectrophotometer supplied with mains lead and dual cell holder (for 10mm square cuvettes and 12.7mm diameter tubes)

 

• Wavelength range of 320 to 1000nm
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessories
• Domed lid of 6320D accepts tubes up to 105mm tall

The 6320D are high quality, low cost unit for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries. The 6320D is based on the 6300 platform and includes a domed lid which accepts taller tubes up to a height of 105mm.

Parameter Jenway 6320D Spectrophotometers
Wavelength range 320 to 1000nm
Wavelength resolution 1nm
Wavelength accuracy ±2nm
Spectral bandwidth 8nm
Transmittance 0 to 199.9%T
Absorbance –0.300 to 1.999A
Accuracy ±1%T
Resolution 0.1%T, 0.001A
Stray light <0.5%T
Noise <1%
Stability 1%/h after 15 minutes
Concentration range –300 to 1999
Concentration resolution 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999
Light source Tungsten halogen lamp
Outputs Analogue and RS232
Power <50W
Size (w x d x h) 365 x 272 x 160mm
Weight 6kg

 


Availability: IN STOCK
SKU# 6305

UV/visible spectrophotometer supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, interface cable and PC application software on CD-ROM*

 

• Wavelength range of 198 to 1000nm 
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessoriesl
• 6305 utilises a high quality pulsed xenon lamp
• Wide range of sampling accessories

The 6305 are high quality, low cost unit for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries.  

Technical Specification
 
Parameter 6305
Wavelength range 198 to 1000nm
Wavelength resolution 1nm
Wavelength accuracy ±2nm
Spectral bandwidth 8nm, 6nm over UV range
Transmittance 0 to 199.9%T
Absorbance –0.300 to 1.999A
Accuracy ±1%T
Resolution 0.1%T, 0.001A
Stray light <0.5%T at 220 and 340nm
Noise <0.001A at 0A at 400nm
Stability <0.002A/h after 30 minutes
Concentration range –300 to 1999
Concentration resolution 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999
Light source Xenon lamp
Outputs Analogue and RS232
Power <50W
Size (w x d x h) 365 x 272 x 160mm
Weight 6kg
  


Availability: IN STOCK
SKU# 7300

Visible range, 5nm spectrophotometer fitted with 10x10mm cuvette holder, supplied with pack 100 disposable cuvettes, instruction manual, universal power supply, PC software on CD ROM and interface cable

• Icon driven software
• Small footprint
• Autologging capabilities 
• Press to read xenon lamp (7305) 
• Extensive range of accessories available

The Jenway 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7300 and 7305 feature measurement modes for absorbance, % transmittance and concentration. 

All of the models in the Jenway 73 series range are covered by a three year warranty which includes the xenon lamp. These spectrophotometers are easy to use and ideal for use in education and general QC laboratories. 

Technical Specification

Parameter

Jenway 7300 Spectrophotometer

Wavelength Range

320 to 1000nm

Light source

Tungsten halogen lamp

Resolution

1nm

Accuracy

± 2nm

Repeatibility

± 0.5nm

Spectral bandwidth

5nm

Photometric Transmittance

0 to 199.9%

Photometric Absorbance

-0.300 to 2.500

Photometric Accuracy

± 1%T, ± 0.01Abs at 1.000 Absorbance

Photometric Resolution

0.1%T, 0.001A

Concentration Range

-300 to 9999

Concentration Resolution

Selectable 1/0.1/0.01/0.001

 


Availability: IN STOCK
Price: €0.00

SKU# 7310

Visible range, 5nm scanning spectrophotometer fitted with 10x10mm cuvette holder, supplied with pack 100 disposable cuvettes, instruction manual, universal power supply, USB memory stick, PC software on CD ROM and interface cablemanual, universal power supply, PC software on CD ROM and interface cable

  • Icon driven software
  • Results and method saving to USB memory stick
  • Autologging capabilities
  • Press to read xenon lamp (7315)
  • 3 year warranty including xenon lamp

****Extensive range of accessories available

The Jenway 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7310 and 7315 feature measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.

The advanced models have the additional feature of an easy access USB port on the front of the unit which enables results to be stored directly to a USB memory stick for easy transfer of data. These models can also store up to 240 methods which can be copied from one unit to another using the USB capability.

The Jenway 7310 and 7315 models have enhanced security features enabling the settings and methods to be locked preventing unauthorised changes to the instrument settings and method parameters. The home page can also be customised and selected modes restricted, which is ideal for teaching laboratories. 

The 73 series spectrophotometers are all covered by a three year warranty which includes the xenon lamp. 

Parameter
Jenway 7310 Spectrophotometer
Wavelength Range
320 to 1000nm
Light source
Tungsten halogen lamp
Resolution
1nm
Accuracy
± 2nm
Repeatibility
± 0.5nm
Spectral bandwidth
5nm
Photometric Transmittance
0 to 199.9%
Photometric Absorbance
-0.300 to 2.500
Photometric Accuracy
± 1%T, ± 0.01Abs at 1.000 Absorbance
Photometric Resolution
0.1%T, 0.001A
Concentration Range
-300 to 9999
Concentration Resolution
selec table 1/ 0.1/ 0.01/ 0.001
Concentation Calibration
Blank with a single standard or factor
Concentration Units
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l
Concentration Factor
0.001 to 10000
Concentration Standard
0.001 to 1000
Quantitation Range
-300 to 9999
Quantitation Resolution
selec table 1/ 0.1/ 0.01/ 0.001
Quantitation Calibration
Blank with up to 6 standards
Quantitation Curve fit algorithms
Quadratic, quadratic through zero, linear, linear through zero, interpolate
Kinetics Measurement time
2 to 9999 seconds
Kinetics Calibration
Blank with a single standard or factor
Kinetics Display
Graphical and concentration
Kinetics Analysis
Concentration, rate of change, initial and final absorbance/%T
Kinetics Resolution
selec table 1/ 0.1/ 0.01/ 0.001
Spectrum Range
320 to 1000nm
Spectrum Scan interval
selec table 1, 2 or 5nm
Spectrum Analysis
Absorbance or transmittance and peak and valleys
GLP
Current time and date, user ID, instrument lock and method lock
Method storage
240
Results memory
Limited by attached mass storage device
Removable media
USB (supplied)
Outputs
USB, Analogue, RS232, Integral printer
Size (w x d x h)
275 x 400 x 220mm
Weight
6kg


Availability: IN STOCK
Price: €0.00

SKU# 7305

7305 UV/Visible spectrophotometer fitted with 10x10mm cuvette holder, supplied with pack 100 disposable cuvettes, instruction manual, universal power supply, PC software on CD ROM and interface cable

• Icon driven software
• Small footprint
• Autologging capabilities 
• Press to read xenon lamp (7305) 
• Extensive range of accessories available

The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7300 and 7305 feature measurement modes for absorbance, % transmittance and concentration. 

All of the models in the 73 series range are covered by a three year warranty which includes the xenon lamp. These spectrophotometers are easy to use and ideal for use in education and general QC laboratories. 

 

Technical Specficiation

Parameter
Jenway 7305 Spectrophotometer
Wavelength Range
198 to 1000nm
Light source
Xenon lamp
Resolution
1nm
Accuracy
± 2nm
Repeatibility
± 0.5nm
Spectral bandwidth
5nm
Photometric Transmittance
0 to 199.9%
Photometric Absorbance
-0.300 to 2.500
Photometric Accuracy
± 1%T, ± 0.01Abs at 1.000 Absorbance
Photometric Resolution
0.1%T, 0.001A
Concentration Range
-300 to 9999
Concentration Resolution
Selectable 1/0.1/0.01/0.001
Concentation Calibration
Blank with a single standard or factor
Concentration Units
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, �M, nM, U, U/l, U/ml, g/l, mg/l, �g/l, ng/l, g/dl, mg/dl, �g/dl, mg/ml, �g/ml, ng/ml, �g/ul, ng/ul, mol/l, mmol/l
Concentration Factor
0.001 to 10000
Concentration Standard
0.001 to 1000
Outputs
Analogue, RS232, Integral printer
Size (w x d x h)
275 x 400 x 220mm
Weight
6kg


Availability: IN STOCK
Price: €0.00

SKU# 7315

UV/Visible, scanning spectrophotometer fitted with 10x10mm cuvette holder, supplied with pack 100 disposable cuvettes, instruction manual, universal power supply, USB memory stick, PC software on CD ROM and interface cable

  • Icon driven software

  • Results and method saving to USB memory stick

  • Autologging capabilities

  • Press to read xenon lamp

  • 3 year warranty including xenon lamp

****Extensive range of accessories available

The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The 7315 feature measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.

The advanced models have the additional feature of an easy access USB port on the front of the unit which enables results to be stored directly to a USB memory stick for easy transfer of data. These models can also store up to 240 methods which can be copied from one unit to another using the USB capability.

The 7315 model has enhanced security features enabling the settings and methods to be locked preventing unauthorised changes to the instrument settings and method parameters. The home page can also be customised and selected modes restricted, which is ideal for teaching laboratories. 

The 73 series spectrophotometers are all covered by a three year warranty which includes the xenon lamp. 

Technical Specification 

Parameter

Jenway 7315 Spectrophotometer

Wavelength Range

198 to 1000nm

Light source

Xenon lamp

Resolution

1nm

Accuracy

± 2nm

Repeatibility

± 0.5nm

Spectral bandwidth

5nm

Photometric Transmittance

0 to 199.9%

Photometric Absorbance

-0.300 to 2.500

Photometric Accuracy

± 1%T, ± 0.01Abs at 1.000 Absorbance

Photometric Resolution

0.1%T, 0.001A

Concentration Range

-300 to 9999

Concentration Resolution

selec table 1/ 0.1/ 0.01/ 0.001

Concentation Calibration

Blank with a single standard or factor

Concentration Units

no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l

Concentration Factor

0.001 to 10000

Concentration Standard

0.001 to 1000

Quantitation Range

-300 to 9999

Quantitation Resolution

selec table 1/ 0.1/ 0.01/ 0.001

Quantitation Calibration

Blank with up to 6 standards

Quantitation Curve fit algorithms

Quadratic, quadratic through zero, linear, linear through zero, interpolate

Kinetics Measurement time

2 to 9999 seconds

Kinetics Calibration

Blank with a single standard or factor

Kinetics Display

Graphical and concentration

Kinetics Analysis

Concentration, rate of change, initial and final absorbance/:%T

Kinetics Resolution

selec table 1/ 0.1/ 0.01/ 0.001

Spectrum Range

198 to 1000nm

Spectrum Scan interval

selec table 1, 2 or 5nm

Spectrum Analysis

Absorbance or transmittance and peak and valleys

GLP

Current time and date, user ID, instrument lock and method lock

Method storage

240

Results memory

Limited by attached mass storage device

Removable media

USB (supplied)

Outputs

USB, Analogue, RS232, Integral printer

Size (w x d x h)

275 x 400 x 220mm

Weight

6kg

 


Availability: IN STOCK
Price: €0.00

SKU# 6700

Visible range, 4nm SBW spectrophotometer fitted with single 10 x 10 mm cuvette holder, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, power cable and PC software on CD ROM with interface cable.

 

 

• Colour touch screen display
• High quality, sealed split beam optics for optimum photometric performance
• Secure multi-user operation
• Save to SD/USB memory cards
• Enhanced productivity
• Extensive range of accessories for flexibility and improve productivity

All three instruments have modes for photometrics, spectrum scanning, multi-wavelength analysis, kinetics and quantitation, giving direct concentration results against single or multi-point calibrations. With extensive post measurement tools to ensure results are presented exactly to each users requirements the 67 series also offers significant advances in data portability.

Together, the touch screen and colour display give the fastest, most flexible instrument interface possible. Where fine cursor control is required, using the QWheel™ makes the task easy and precise.

Jenway have developed Secure Multi User Operation for when instruments are shared by a number of users, so access to the instrument functions is controlled through a secure log-in procedure. For maximum security PIN codes can be allocated to individuals, groups or departments and to further increase flexibility each method can be given three levels of security:

• Public access is free to all users.
• Read only methods can be accessed by all users, but only modified by the originator.
• Personal method can only be accessed by the logged in user

The high capacity internal memory of the 67 series can be configured from 256MB, enabling over 1000 methods and results to be stored, up to 2GB, which stores more than 10,000 methods and results.

Removable SD or SD/USB memory cards further increases the flexibility and data transfer and enables the direct transfer of results to a PC via a USB port. Here all data can be viewed, exported, saved or printed for generating reports and standard operating procedures. Copying the SD card to the instrument's internal memory enables the easy cloning of multiple instruments, ensuring common laboratory practice and speeding set-up in busy teaching establishments.

QWheel is a registered trademark of Quantum Research

Technical Specification

Parameter 6700
Wavelength range 320 to 1100nm 
Wavelength resolution 0.1nm
Wavelength accuracy ±1.0nm
Wavelength repeatability ±0.2nm
Spectral bandwidth 4nm 
Transmittance 0 to 199.9%T
Absorbance –0.300 to 3.000A
Accuracy ±0.005A at 1.0A
Resolution 0.1%T, 0.001A
Stray light <0.1%T at 340nm 
Noise <0.001 at 0A, <0.002 at 2A at 340nm
Stability <0.001A/h after warm–up
Quantitation range –99999 to +99999
Quantitation resolution Selectable 1, 0.1, 0.01 or 0.001
Calibration Up to 20 with 5 replicates of each
Units mEq/l, ppm, mg/l, g/l, %, µg/ml, mg/ml, g/dl, mg/dl, µg/l, ng/l, µg/dl, M, mM, µM, U/l, mU/l, U/ml, blank
Curve fit algorithms Linear, quadratic and cubic functions
Multi–wavelength Up to 4 wavelengths
Calculations Ratio, difference, formulae with factors
Kinetics time limits 0 to 9999 seconds
Calibration Standard or factor
Analysis Curve details with mean rate of change plus formula of line of best fit
Spectrum range Any range between 320
Scan speed 1500nm/min
Scan interval 0.1nm
Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, analysis points, overlay
Light source Tungsten halogen lamp 
Configuration Secure multi–user and free access
Number of users 10 users + supervisor
Methods/results memory >1000 on internal flash memory or removable media
Removable media MM/SD memory card or SD/USB memory card
Outputs USB, Centronics, Analogue
Size (w x d x h) 490 x 390 x 220mm
Weight 7.5kg


Availability: IN STOCK
Price: €0.00

SKU# 6705

UV/Visible range, 4nm SBW spectrophotometer fitted with single 10 x 10 mm cuvette holder, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, power cable and PC software on CD ROM with interface cable.

 

• Colour touch screen display
• High quality, sealed split beam optics for optimum photometric performance
• Secure multi-user operation
• Save to SD/USB memory cards
• Enhanced productivity
• Extensive range of accessories for flexibility and improve productivity

All three instruments have modes for photometrics, spectrum scanning, multi-wavelength analysis, kinetics and quantitation, giving direct concentration results against single or multi-point calibrations. With extensive post measurement tools to ensure results are presented exactly to each users requirements the 67 series also offers significant advances in data portability.

Together, the touch screen and colour display give the fastest, most flexible instrument interface possible. Where fine cursor control is required, using the QWheel™ makes the task easy and precise.

Jenway have developed Secure Multi User Operation for when instruments are shared by a number of users, so access to the instrument functions is controlled through a secure log-in procedure. For maximum security PIN codes can be allocated to individuals, groups or departments and to further increase flexibility each method can be given three levels of security:

• Public access is free to all users.
• Read only methods can be accessed by all users, but only modified by the originator.
• Personal method can only be accessed by the logged in user

The high capacity internal memory of the 67 series can be configured from 256MB, enabling over 1000 methods and results to be stored, up to 2GB, which stores more than 10,000 methods and results.

Removable SD or SD/USB memory cards further increases the flexibility and data transfer and enables the direct transfer of results to a PC via a USB port. Here all data can be viewed, exported, saved or printed for generating reports and standard operating procedures. Copying the SD card to the instrument's internal memory enables the easy cloning of multiple instruments, ensuring common laboratory practice and speeding set-up in busy teaching establishments.

QWheel is a registered trademark of Quantum Research

Technical Specification

 

Parameter 6705
Wavelength range 190 to 1100nm 
Wavelength resolution 0.1nm
Wavelength accuracy ±1.0nm
Wavelength repeatability ±0.2nm
Spectral bandwidth 4nm 
Transmittance 0 to 199.9%T
Absorbance –0.300 to 3.000A
Accuracy ±0.005A at 1.0A
Resolution 0.1%T, 0.001A
Stray light <0.05% at 220nm
Noise <0.001 at 0A, <0.002 at 2A at 340nm
Stability <0.001A/h after warm–up
Quantitation range –99999 to +99999
Quantitation resolution Selectable 1, 0.1, 0.01 or 0.001
Calibration Up to 20 with 5 replicates of each
Units mEq/l, ppm, mg/l, g/l, %, µg/ml, mg/ml, g/dl, mg/dl, µg/l, ng/l, µg/dl, M, mM, µM, U/l, mU/l, U/ml, blank
Curve fit algorithms Linear, quadratic and cubic functions
Multi–wavelength Up to 4 wavelengths
Calculations Ratio, difference, formulae with factors
Kinetics time limits 0 to 9999 seconds
Calibration Standard or factor
Analysis Curve details with mean rate of change plus formula of line of best fit
Spectrum range Any range between 190  and 1100nm
Scan speed 1500nm/min
Scan interval 0.1nm
Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, analysis points, overlay
Light source Xenon lamp
Configuration Secure multi–user and free access
Number of users 10 users + supervisor
Methods/results memory >1000 on internal flash memory or removable media
Removable media MM/SD memory card or SD/USB memory card
Outputs USB, Centronics, Analogue
Size (w x d x h) 490 x 390 x 220mm
Weight 7.5kg

 


Availability: IN STOCK
Price: €0.00

SKU# 6715

UV/Visible range, 1.5nm SBW spectrophotometer fitted with single 10 x 10 mm cuvette holder, 1GB of internal memory, 1GB SD/USB memory card, 100 disposable cuvettes, instruction manual, power cable and PC software on CD ROM with interface cable.

 

• Colour touch screen display
• High quality, sealed split beam optics for optimum photometric performance
• Secure multi-user operation
• Save to SD/USB memory cards
• Enhanced productivity
• Extensive range of accessories for flexibility and improve productivity

All three instruments have modes for photometrics, spectrum scanning, multi-wavelength analysis, kinetics and quantitation, giving direct concentration results against single or multi-point calibrations. With extensive post measurement tools to ensure results are presented exactly to each users requirements the 67 series also offers significant advances in data portability.

Together, the touch screen and colour display give the fastest, most flexible instrument interface possible. Where fine cursor control is required, using the QWheel™ makes the task easy and precise.

Jenway have developed Secure Multi User Operation for when instruments are shared by a number of users, so access to the instrument functions is controlled through a secure log-in procedure. For maximum security PIN codes can be allocated to individuals, groups or departments and to further increase flexibility each method can be given three levels of security:

• Public access is free to all users.
• Read only methods can be accessed by all users, but only modified by the originator.
• Personal method can only be accessed by the logged in user

The high capacity internal memory of the 67 series can be configured from 256MB, enabling over 1000 methods and results to be stored, up to 2GB, which stores more than 10,000 methods and results.

Removable SD or SD/USB memory cards further increases the flexibility and data transfer and enables the direct transfer of results to a PC via a USB port. Here all data can be viewed, exported, saved or printed for generating reports and standard operating procedures. Copying the SD card to the instrument's internal memory enables the easy cloning of multiple instruments, ensuring common laboratory practice and speeding set-up in busy teaching establishments.

QWheel is a registered trademark of Quantum Research

Technical Specification

 

Parameter 6715
Wavelength range 190 to 1100nm
Wavelength resolution 0.1nm
Wavelength accuracy ±1.0nm
Wavelength repeatability ±0.2nm
Spectral bandwidth 1.5nm 
Transmittance 0 to 199.9%T
Absorbance –0.300 to 3.000A
Accuracy ±0.005A at 1.0A
Resolution 0.1%T, 0.001A
Stray light  <0.05% at 220nm 
Noise <0.001 at 0A, <0.002 at 2A at 340nm
Stability <0.001A/h after warm–up
Quantitation range –99999 to +99999
Quantitation resolution Selectable 1, 0.1, 0.01 or 0.001
Calibration Up to 20 with 5 replicates of each
Units mEq/l, ppm, mg/l, g/l, %, µg/ml, mg/ml, g/dl, mg/dl, µg/l, ng/l, µg/dl, M, mM, µM, U/l, mU/l, U/ml, blank
Curve fit algorithms Linear, quadratic and cubic functions
Multi–wavelength Up to 4 wavelengths
Calculations Ratio, difference, formulae with factors
Kinetics time limits 0 to 9999 seconds
Calibration Standard or factor
Analysis Curve details with mean rate of change plus formula of line of best fit
Spectrum range Any range between 190 and 1100nm
Scan speed 1500nm/min
Scan interval 0.1nm
Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, analysis points, overlay
Light source Xenon lamp
Configuration Secure multi–user and free access
Number of users 10 users + supervisor
Methods/results memory >1000 on internal flash memory or removable media
Removable media MM/SD memory card or SD/USB memory card
Outputs USB, Centronics, Analogue
Size (w x d x h) 490 x 390 x 220mm
Weight 7.5kg

 


Availability: IN STOCK
Price: €0.00

SKU# 630 501

Model 6300 Visible range Spectrophotometer (320-1000nm) supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, PC Application Software on CD-ROM and operating instructions, for use on 230V/50Hz.

• Wavelength range of 320 to 1000nm (6300 and 6320D) or 198 to 1000nm (6305)
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessories
• Domed lid of 6320D accepts tubes up to 105mm tall
• 6305 utilises a high quality pulsed xenon lamp
• 3 year warranty

The Jenway 6300 and Jenway 6305 visible and UV/visible spectrophotometers are high quality, low cost units for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries. The 6320D is based on the 6300 visible spectrophotometer platform and includes a domed lid which accepts taller tubes up to a height of 105mm.

Technical Specification

 

Parameter 6300 and 6320D 6305
Wavelength range 320 to 1000nm 198 to 1000nm
Wavelength resolution 1nm 1nm
Wavelength accuracy ±2nm ±2nm
Spectral bandwidth 8nm 8nm, 6nm over UV range
Transmittance 0 to 199.9%T 0 to 199.9%T
Absorbance –0.300 to 1.999A –0.300 to 1.999A
Accuracy ±1%T ±1%T
Resolution 0.1%T, 0.001A 0.1%T, 0.001A
Stray light <0.5%T <0.5%T at 220 and 340nm
Noise <1% <0.001A at 0A at 400nm
Stability 1%/h after 15 minutes <0.002A/h after 30 minutes
Concentration range –300 to 1999 –300 to 1999
Concentration resolution 0.1 to 1 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999 0 to 199.9, 1000 to 9999
Light source Tungsten halogen lamp Xenon lamp
Outputs Analogue and RS232 Analogue and RS232
Power <50W <50W
Size (w x d x h) 365 x 272 x 160mm 365 x 272 x 160mm
Weight 6kg 6kg

Availability: IN STOCK
SKU# 635 001

Model 6305 UV/Visible range Spectrophotometer (190-1000nm) supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, PC Application Software on CD-ROM and operating instructions, for use on 50/60Hz. 115-230 Volts

  

• Wavelength range of 198 to 1000nm 
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessoriesl
• 6305 utilises a high quality pulsed xenon lamp
• Wide range of sampling accessories

The 6305 are high quality, low cost unit for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries.  

Technical Specification
 
Parameter 6305
Wavelength range 198 to 1000nm
Wavelength resolution 1nm
Wavelength accuracy ±2nm
Spectral bandwidth 8nm, 6nm over UV range
Transmittance 0 to 199.9%T
Absorbance –0.300 to 1.999A
Accuracy ±1%T
Resolution 0.1%T, 0.001A
Stray light <0.5%T at 220 and 340nm
Noise <0.001A at 0A at 400nm
Stability <0.002A/h after 30 minutes
Concentration range –300 to 1999
Concentration resolution 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999
Light source Xenon lamp
Outputs Analogue and RS232
Power <50W
Size (w x d x h) 365 x 272 x 160mm
Weight 6kg
  

Availability: IN STOCK
SKU# 632 501

Model 6320D Visible range Spectrophotometer (320-1000nm), fitted with domed lid, supplied with mains lead, dual cell holder (for 10mm square cuvettes and 12.7mm diameter tubes) and operating instructions, for use on 230V/50Hz.

• Wavelength range of 320 to 1000nm (6300 and 6320D) or 198 to 1000nm (6305)
• Absorbance, %T and concentration modes
• Multi-parameter display with wavelength and photometric readouts
• Wide range of sampling accessories
• Domed lid of 6320D accepts tubes up to 105mm tall
• 6305 utilises a high quality pulsed xenon lamp
• 3 year warranty

The Jenway 6300 and Jenway 6305 visible and UV/visible spectrophotometers are high quality, low cost units for spectrophotometric applications in schools and colleges, as well as in QC and testing procedures for a wide variety of services and industries. The 6320D is based on the 6300 visible spectrophotometer platform and includes a domed lid which accepts taller tubes up to a height of 105mm.

Technical Specification

 

Parameter 6300 and 6320D 6305
Wavelength range 320 to 1000nm 198 to 1000nm
Wavelength resolution 1nm 1nm
Wavelength accuracy ±2nm ±2nm
Spectral bandwidth 8nm 8nm, 6nm over UV range
Transmittance 0 to 199.9%T 0 to 199.9%T
Absorbance –0.300 to 1.999A –0.300 to 1.999A
Accuracy ±1%T ±1%T
Resolution 0.1%T, 0.001A 0.1%T, 0.001A
Stray light <0.5%T <0.5%T at 220 and 340nm
Noise <1% <0.001A at 0A at 400nm
Stability 1%/h after 15 minutes <0.002A/h after 30 minutes
Concentration range –300 to 1999 –300 to 1999
Concentration resolution 0.1 to 1 0.1 to 1
Units ppm, mg/l, g/l, M, %, blank ppm, mg/l, g/l, M, %, blank
Factor 0 to 199.9, 1000 to 9999 0 to 199.9, 1000 to 9999
Light source Tungsten halogen lamp Xenon lamp
Outputs Analogue and RS232 Analogue and RS232
Power <50W <50W
Size (w x d x h) 365 x 272 x 160mm 365 x 272 x 160mm
Weight 6kg 6kg

 


Availability: IN STOCK
SKU# 6850/230V

Model 6850 Variable Bandwidth Double Beam Spectrophotometer supplied with single cuvette holders (for 10 x 10mm cuvettes in sample and ref), Prism PC Software on CD ROM, USB stick, USB connection cable and dongle, 2 x quartz cuvettes, 4 x glass cuvettes, FREE dust cover and 230V power supply.

  • Double beam spectrophotometer with highly stable optics
  • Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
  • Integrated user interface
  • Conforms to European Pharmacopeia requirements
  • Jenway Prism PC software included as standard
  • Extensive range of accessories available

The new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis.

Jenway Prism PC software is supplied as standard and offers additional functionality with preloaded methods for DNA/RNA and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data.

The 6850 is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.
 

Technical Specification

Parameter

Jenway 6850 Spectrophotometer

Wavelength range

190 to 1100nm

Wavelength resolution

0.1nm

Wavelength accuracy

± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth)

Wavelength reproducibility

± 0.2nm

Spectral bandwidth

Variable 0.5, 1, 2, 4, 5nm

Photometric range

- 0.3 to 3.0A 0 to 200%T

Photometric accuracy

± 0.002A (0- 0.5A) ± 0.3% T (0- 100%T)

Photometric reproducibility

± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15%T (0- 100%T)

Resolution

0.1%T, 0.001A

Stray light

< 0.05%T at 220 and 360nm

Noise

0.0005A

Stability

± 0.001A/h at 500nm after 15 min warm up

Multi-wavelength

Up to 10 wavelengths, up to 20 wavelengths with PC software

Calculations

Ratio, difference, formulae with factors

Spectrum range

Any range between 190 and 1100nm

Scan speed

100 to 2000nm/min

Scan interval

0.1, 0.2, 0.5, 1, 2 or 5nm

Analysis

Auto peaks and valleys, zoom . Addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, overlay with PC software

Kinetics

Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds

Analysis

Slope and formula of line of best fit between any two points

Quantitation points

Up to 3 wavelengths

Quantitation Calibration

Blank with up to 10 standards or factor

Concentration range

0- 99999

Calibration

Blank with standards or factor

DNA/ RNA and Protein

DNA/RNA Ratio, concentration, A320 correction

Light source

Tungsten halogen and Deuterium lamps

Lamp changeover

325 to 370nm selec table

Outputs

USB and parallel

Operating system:

Windows 2000, XP, Vista, Windows 7

Electrical supply

120VA, 220/ 110V, 50/ 60Hz

Size (w x d x h)

600 x 450 x 200mm

Weight

22kg

 

 


Availability: IN STOCK
SKU# 720001

7200 visible scanning spectrophotometer fitted with 10x10mm cuvette holder, supplied with instruction manual and universal power supply with UK EU and US power leads

 • Scanning diode array technology

• Colour touchscreen navigation
• Small footprint and lightweight 
• Fast scan speed
• English, French and German language options 
• Multiple USB ports for data storage and printer connectivity
• Extensive range of accessories available
• 2 year warranty (including xenon lamp)

The 72 series spectrophotometers are the first scanning spectrophotometers in the Jenway range to leverage diode array technology to produce exceptionally fast results. The range includes two models: model 7200 covers a wavelength range of 335 to 800nm with a spectral bandwidth of 7nm and model 7205 covers a wavelength range of 198 to 800nm with a spectral bandwidth of 5nm.

Both spectrophotometers are ideal for a variety of applications in education and routine testing in clinical, veterinary, pharmaceutical and QC laboratories. 

The 72 series spectrophotometers offer measurement modes for single wavelength with basic absorbance and % transmittance; concentration calculated using a standard or a factor; optical density; quantitation with the ability to create a calibration curve using up to 6 standards and 3 replicates; full spectrum scanning and kinetics where up to 3 wavelengths can be measured simultaneously.

The colour touchscreen user interface provides fast and easy set up and navigation of the instrument. The 4" display allows full spectrum scans, quantitation curves and kinetics runs to be viewed easily. The touchscreen capability enables users to zoom in and out and select spectral analysis points all by simply tapping the screen. 

The large sample chamber will easily accommodate the optional long path length cuvette holder and the heated 10x10mm cuvette holder which is ideal for thermostated measurements at 37°C. The sample chamber lid can also be left open during measurements which is ideal for samples in tall test tubes. 

There are two USB ports for data storage and printer connectivity. The easy access USB port on the front of the instrument can be used to easily store results and quantitation curves.
 

To take a tour round the intuitve user interface click here to use our simulator.

Technical Specification

 

Model 7200 7205
Wavelength Range 335 to 800nm 198 to 800nm
Wavelength Accuracy ± 2nm ± 2nm
Wavelength Repeatability ± 2nm ± 2nm
Spectral Bandwidth 7nm 5nm
Absorbance Range - 0.300 to 2.500A - 0.300 to 2.500A
Absorbance Accuracy ± 0.01A at 1.0A and 546nm ± 0.01A at 1.0A and 546nm
Absorbance Stability (A) ± 0.005A/h at 0.04A and 546nm ± 0.005A/h at 0.04A and 546nm
Noise ± 0.002A at 0.1A and ± 0.02A at 2.0A and 546nm ± 0.002A at 0.1A and ± 0.02A at 2.0A and 546nm
Stray Light at 340nm, %T < 1%T according to ANSI/ASTM E387- 72 < 1%T according to ANSI/ASTM E387- 72
Concentration Range ± 2500 ± 2500
Concentration Calibration Blank with a single standard or factor Blank with a single standard or factor
Concentration Factor ± 1000 ± 1000
Concentration Standard ± 1000 ± 1000
Optical Density Factor ± 1000 ± 1000
Quantitation Range ± 2500 ± 2500
Quantitation Calibration Blank with up to 6 standards Blank with up to 6 standards
Curve Fit Algorithms Linear and linear through zero Linear and linear through zero
Kinetics Measurement Time 15 to 9999 seconds 7 to 9999 seconds
Kinetics Number of wavelengths 3 3
Kinetics Calibration Blank with a factor Blank with a factor
Kinetics Display Graphical, rate of change and concentration Graphical, rate of change and concentration
Kinetics Analysis Concentration Concentration
Spectrum Range 335 to 800nm 198 to 800nm
Spectrum Analysis Absorbance or % transmittance and up to 50 spectral analysis points Absorbance or % transmittance and up to 50 spectral analysis points
Beam Height 15mm 15mm
Light Source Tungsten Halogen lamp Xenon lamp
Results Memory Limited by attached USB memory stick Limited by attached USB memory stick
Removable Media USB USB
Outputs USB x 2 USB x 2
Supply voltage/frequency 100 - 240VAC at 50 to 60Hz 100 - 240VAC at 50 to 60Hz
Power Supply 12V DC, 3.8A 12V DC, 3.8A
Size (w x d x h) 212 x 422 x 120mm 212 x 422 x 120mm
Weight 2.8kg 2.8kg
Warranty 2 years on the instrument, 1 year on the lamp 2 years on the instrument, 2 years on the lamp

Availability: IN STOCK
SKU# 7200

Visible Scanning Spectrophotometer, fitted with 10 x 10 mm cuvette holder, supplied with instruction manual and universal power supply with UK EU and US power leads

• Scanning diode array technology
• Colour touchscreen navigation
• Small footprint and lightweight
• Fast scan speed
• French language option
• Multiple USB ports for data storage and printer connectivity
• Extensive range of accessories available
• 2 year warranty

Model 7200 is the first visible scanning spectrophotometer in the Jenway range to leverage diode array technology to produce fast results. Covering a wavelength range of 335 to 800nm, with a spectral bandwidth of 7nm, this spectrophotometer is ideal for a variety of applications in education and routine testing in clinical, veterinary, pharmaceutical and QC laboratories.

Model 7200 offers measurement modes for single wavelength with basic absorbance and % transmittance; concentration calculated using a standard or a factor; optical density; quantitation with the ability to create a calibration curve using up to 6 standards and 3 replicates; full spectrum scanning and kinetics where up to 3 wavelengths can be measured simultaneously.

The colour touchscreen user interface provides fast and easy set up and navigation of the instrument. The 4" display allows full spectrum scans, quantitation curves and kinetics runs to be viewed easily. The touchscreen capability enables users to zoom in and out and select spectral analysis points all by simply tapping the screen.

The large sample chamber will easily accommodate the optional long path length cuvette holder and the heated 10x10mm cuvette holder which is ideal for thermostated measurements at 37°C. The sample chamber lid can also be left open during measurements which is ideal for samples in tall test tubes.

There are two USB ports for data storage and printer connectivity. The easy access USB port on the front of the instrument can be used to easily store results and quantitation curves. 

Technical Specification
Wavelength Range 335 to 800nm
Wavelength Accuracy ± 2nm
Wavelength Repeatability ± 2nm
Spectral Bandwidth 7nm
Absorbance Range - 0.300 to 2.500A
Absorbance Accuracy ± 0.01A at 1.0A and 546nm
Absorbance Stability (A) ± 0.005A/h at 0.04A and 546nm
Noise ± 0.002A at 0.04A and ± 0.02A at 2.0A and 546nm
Stray Light at 340nm, %T < 1%T according to ANSI/ASTM E387- 72
Concentration Range ± 2500
Concentration Calibration Blank with a single standard or factor
Concentration Factor ± 1000
Concentration Standard ± 1000
Optical Density Factor ± 1000
Quantitation Range ± 2500
Quantitation Calibration Blank with up to 6 standards
Curve Fit Algorithms Linear and linear through zero
Kinetics Measurement Time 15 to 9999 seconds
Kinetics Number of wavelengths 3
Kinetics Calibration Blank with a factor
Kinetics Display Graphical and concentration
Kinetics Analysis Concentration
Spectrum Range 335 to 800nm
Spectrum Analysis Absorbance or % transmittance and up to 50 spectral analysis points
Beam Height 15mm
Light Source Tungsten Halogen lamp
Results Memory Limited by attached USB memory stick
Removable Media USB
Outputs USB x 2
Supply voltage/frequency 100 - 240VAC at 50 to 60Hz
Power Supply 12V DC, 3.8A
Size (w x d x h) 212 x 422 x 120mm
Weight 2.8kg
Warranty 2 years on the instrument, 1 year on the lamp

Availability: IN STOCK
SKU# 720501

7205 UV/visible scanning spectrophotometer fitted with 10x10mm cuvette holder, supplied with instruction manual and universal power supply with UK EU and US power leads

 Scanning diode array technology
• Colour touchscreen navigation
• Small footprint and lightweight 
• Fast scan speed
• English, French and German language options 
• Multiple USB ports for data storage and printer connectivity
• Extensive range of accessories available
• 2 year warranty (including xenon lamp)

The 72 series spectrophotometers are the first scanning spectrophotometers in the Jenway range to leverage diode array technology to produce exceptionally fast results. The range includes two models: model 7200 covers a wavelength range of 335 to 800nm with a spectral bandwidth of 7nm and model 7205 covers a wavelength range of 198 to 800nm with a spectral bandwidth of 5nm.

Both spectrophotometers are ideal for a variety of applications in education and routine testing in clinical, veterinary, pharmaceutical and QC laboratories. 

The 72 series spectrophotometers offer measurement modes for single wavelength with basic absorbance and % transmittance; concentration calculated using a standard or a factor; optical density; quantitation with the ability to create a calibration curve using up to 6 standards and 3 replicates; full spectrum scanning and kinetics where up to 3 wavelengths can be measured simultaneously.

The colour touchscreen user interface provides fast and easy set up and navigation of the instrument. The 4" display allows full spectrum scans, quantitation curves and kinetics runs to be viewed easily. The touchscreen capability enables users to zoom in and out and select spectral analysis points all by simply tapping the screen. 

The large sample chamber will easily accommodate the optional long path length cuvette holder and the heated 10x10mm cuvette holder which is ideal for thermostated measurements at 37°C. The sample chamber lid can also be left open during measurements which is ideal for samples in tall test tubes. 

There are two USB ports for data storage and printer connectivity. The easy access USB port on the front of the instrument can be used to easily store results and quantitation curves.
 

To take a tour round the intuitve user interface click here to use our simulator.

Technical Specification
 
Model 7205
Wavelength Range 198 to 800nm
Wavelength Accuracy ± 2nm
Wavelength Repeatability ± 2nm
Spectral Bandwidth 5nm
Absorbance Range
- 0.300 to 2.500A
Absorbance Accuracy
± 0.01A at 1.0A and 546nm
Absorbance Stability (A)
± 0.005A/h at 0.04A and 546nm
Noise
± 0.002A at 0.04A and ± 0.02A at 2.0A and 546nm
Stray Light at 340nm, %T
< 1%T according to ANSI/ASTM E387- 72
Concentration Range ± 2500
Concentration Calibration
Blank with a single standard or factor
Concentration Factor ± 1000
Concentration Standard ± 1000
Optical Density Factor ± 1000
Quantitation Range ± 2500
Quantitation Calibration
Blank with up to 6 standards
Curve Fit Algorithms
Linear and linear through zero
Kinetics Measurement Time
15 to 9999 seconds
Kinetics Number of wavelengths 3
Kinetics Calibration
Blank with a factor
Kinetics Display
Graphical and concentration
Kinetics Analysis Concentration
Spectrum Range 198 to 800nm
Spectrum Analysis
Absorbance or % transmittance and up to 50 spectral analysis points
Beam Height 15mm
Light Source Xenon lamp
Results Memory
Limited by attached USB memory stick
Removable Media USB
Outputs USB x 2
Supply voltage/frequency
100 - 240VAC at 50 to 60Hz
Power Supply 12V DC, 3.8A
Size (w x d x h)
212 x 422 x 120mm
Weight 2.8kg
Warranty
2 years on the instrument, 2 years on the lamp

Availability: IN STOCK
SKU# 741001

7410 visible scanning spectrophotometer, fitted with 10x10mm cuvette holder, and supplied with a universal power supply and an instruction manual

· CPLIVE technology: safely transfer and store data, protocols and results to the free Cloud NEW FEATURE
• 7" High Definition colour touchscreen display
• Android operating system
• Internal memory for methods and results (10GB onboard storage)
• Multiple USB ports for data storage and printer connectivity
• Multi-language options including English, French, German, Spanish and Italian 
• Extensive range of accessories available
• 3-year warranty (excluding Tungsten lamp used on 7410)

The Jneway 74 series spectrophotometers provide accurate and reliable results in various applications from teaching, to industrial applications, to routine sample analysis in quality control environments. These spectrophotometers have been designed to be easy to use and have enhanced connectivity for simple and quick data transfer. All units feature a colour touchscreen and intuitive user interface, allowing manual free operation.

There are two models in the 74 series range. Model 7410 uses a tungsten halogen lamp for measurements in the visible spectrum from 320 to 1000nm. Model 7415 uses a press to read xenon lamp to extend measurements into the UV spectrum, down to 198nm. Both spectrophotometers have a 5nm spectral bandwidth and are covered by a 3-year warranty, including the Xenon lamp used on the 7415 but excluding the Tungsten lamp used on the 7410 which has a 1 year warranty. 

Both models offer measurement modes for simple photometrics; concentration calculated using a single standard or a factor; quantitation with the ability to create a calibration curve using up to 20 standards; full spectrum scanning; multi-wavelength, where up to 4 wavelengths can be measured simultaneously and kinetics, to monitor the change in absorbance over time. 

The large 7" High Definition colour touchscreen enables users to zoom in and out and select points all by simply touching the screen. The touchscreen interface is fast and responsive even when wearing gloves. 

Technical Specification  
   
Parameter 7410
Wavelength Range 320 to 1000nm
Light source Tungsten halogen lamp
Accuracy ± 2nm
Repeatibility ± 0.5nm
Spectral bandwidth 5nm
Photometric Transmittance 0 to 199.9%
Photometric Absorbance - 0.300 to 2.500
Photometric Accuracy ± 1%T, ± 0.01Abs at 1.000 Absorbance
Photometric Resolution 0.1%T, 0.001A
Concentation Calibration Blank with a single standard or factor
Quantitation Calibration Blank with up to 20 standards
Quantitation Curve fit algorithms Quadratic, quadratic through zero, linear, linear through zero, interpolate
Kinetics Analysis Concentration, rate of change, initial and final absorbance/ %T
Spectrum Range 320 to 1000nm
Spectrum Scan interval 1, 2, 5 or 10nm
Spectrum Analysis Absorbance or transmittance, peak and valleys and area under the curve
Internal memory 10GB
External memory Limited by attached mass storage device
Outputs USB Type A x 2, USB Type B x 1, Ethernet connection (RJ45)
Size (w x d x h) 280 x 500 x 156mm
Weight 9kg

 


Availability: IN STOCK
SKU# 7415Nano

7415 Nano spectrophotometer fitted with micro-volume accessory, supplied with universal power supply, calibration standards and certificate and instruction manual. For Volumes as low as 0.5┬Ál

The 7415 Nano measures small sample volumes as low as 0.5µl with a high degree of accuracy, reproducibility and speed. Its ability to measure small sample volumes, reduces the need for dilutions and eliminates the requirement for cuvettes. Cleaning is quick and simple; wiping the read heads with a microfibre cloth removes all trace of the sample, allowing faster change over between samples, therefore increasing sample throughput. 

Key Features
• 7" High Definition colour touchscreen display
• Android operating system
• Features CPLive®
• Ideal for DNA, RNA and Protein measurements
• Only 0.5µl sample volume required
• Purity scan over entire wavelength range, 198 to 1000nm
• Quick and easy to clean
• Detects DNA concentrations as low as 2ng/µl 
• Multiple USB ports for data storage and printer connectivity
• Multi-language options including English, French, German, Spanish and Italian 
• Internal memory for methods and results (10GB onboard storage)
• 3 year warranty including Xenon lamp

Measurement Modes
To make sample measurement even easier the 7415 Nano spectrophotometer is pre-programmed with methods for the measurement of nucleic acid concentrations and purity and protein assays. 

Nucleic Acid Determination Mode
The 7415 Nano is pre-programmed with methods for the measurement of ssDNA, dsDNA, RNA and oligonucleotide concentrations using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. This measurement mode has the 260/280 and 260/230 ratios pre-programmed as well as a variable ratio option which enables up to 3 wavelengths to be entered as well as the correction wavelength. 

Protein Assay Determination Mode
For measuring protein concentrations, the 7415 Nano is pre-programmed with methods for Bradford, Lowry, Biuret, Bicinchoninic Acid (BCA) and Direct UV assays. This measurement mode allows up to 20 standards, with 5 replicates of each standard, to be measured to create the standard curve. The replicate measurements can be set to automatically perform 3 readings one after the other on the same sample; or the replicates can be set to enable one measurement to be performed on three separate samples of the same concentration. 

Purity Scan Measurement Mode
This measurement mode is used to check the purity of nucleic acids. This is especially useful for RNA samples where impurities may be present at 230nm but cannot be detected using the 260/280 ratio measurement. The 7415 Nano enables scanning across the full wavelength range from 198 to 1000nm to identify any distorted peaks.

Micro-volume Spectroscopy 
The 7415 Nano is fitted with a micro-volume accessory which allows samples as small as 0.5µl to be pipetted directly onto the read head, removing the need for cuvettes and conserving precious samples. This makes it ideal for nucleic acid researchers where sample availability may be limited; the perfect analysis tool to measure the purity and concentration of biological samples.

Interface Design
The 74 series spectrophotometers have a custom designed user interface which is based on an Android platform, making it easy to navigate and control the instrument. The home screen gives quick access to the different measurement modes as well as shortcuts to favourites and previously saved methods and results.

Read Head 
Simply pipetting directly onto the read head makes sample measurement, quicker and requires much less effort, eliminating the need for both sample dilutions and cuvettes. The stainless steel read head which consists of a chemically inert embedded quartz lens, utilises the natural surface tension of the droplet to form the bond between the read head surfaces. After measurement the sample can be easily removed by pipetting or wiping away with a micro-fibre cloth.

Fast Readings
The 7415 Nano can automatically take readings at the optimal path length (either 0.2 or 0.5mm). It performs sample measurements in less than 6.5 seconds.

Enhanced Connectivity
The 7415 Nano has been designed with excellent connectivity in mind. The easy access USB ports on the front of the instrument can be used for software updates, data storage and printer connectivity. Results and methods can be stored as CSV files for easy transfer to Microsoft Excel®. With the optional CPLive connectivity protocols and results can be automatically uploaded and stored effortlessly and securely in the cloud. Connect with your personal secured login and password and share your results with colleagues from around the world may you want to.

 

Technical Specification
Outputs USB Type A x 2, USB Type B x 1, Ethernet connection (RJ45)
Supply VoltageFrequency 100 - 240VAC at 50 to 60Hz
Power Supply 24V DC, 2.5A
Dimensions (w x d x h) 280 x 500 x 156mm
Weight 9kg
Warranty 3 years (including xenon lamp)

 


Availability: IN STOCK
SKU# 741501

7415 UV/visible scanning spectrophotometer, fitted with 10x10 cuvette holder, supplied with instruction manual and universal power supply with UK, EU and US power leads

· CPLIVE technology: safely transfer and store data, protocols and results to the free Cloud NEW FEATURE
• 7" High Definition colour touchscreen display
• Android operating system
• Internal memory for methods and results (10GB onboard storage)
• Multiple USB ports for data storage and printer connectivity
• Multi-language options including English, French, German, Spanish and Italian 
• Extensive range of accessories available
• 3-year warranty (excluding Tungsten lamp used on 7410)

The Jneway 74 series spectrophotometers provide accurate and reliable results in various applications from teaching, to industrial applications, to routine sample analysis in quality control environments. These spectrophotometers have been designed to be easy to use and have enhanced connectivity for simple and quick data transfer. All units feature a colour touchscreen and intuitive user interface, allowing manual free operation.

There are two models in the 74 series range. Model 7410 uses a tungsten halogen lamp for measurements in the visible spectrum from 320 to 1000nm. Model 7415 uses a press to read xenon lamp to extend measurements into the UV spectrum, down to 198nm. Both spectrophotometers have a 5nm spectral bandwidth and are covered by a 3-year warranty, including the Xenon lamp used on the 7415 but excluding the Tungsten lamp used on the 7410 which has a 1 year warranty. 

Both models offer measurement modes for simple photometrics; concentration calculated using a single standard or a factor; quantitation with the ability to create a calibration curve using up to 20 standards; full spectrum scanning; multi-wavelength, where up to 4 wavelengths can be measured simultaneously and kinetics, to monitor the change in absorbance over time. 

The large 7" High Definition colour touchscreen enables users to zoom in and out and select points all by simply touching the screen. The touchscreen interface is fast and responsive even when wearing gloves. 
 
Technical Specification  
   
Parameter 741501
Wavelength Range 198 to 1000nm
Light source Xenon lamp
Accuracy ± 2nm
Repeatibility ± 0.5nm
Spectral bandwidth 5nm
Photometric Transmittance 0 to 199.9%
Photometric Absorbance - 0.300 to 2.500
Photometric Accuracy ± 1%T, ± 0.01Abs at 1.000 Absorbance
Photometric Resolution 0.1%T, 0.001A
Concentation Calibration Blank with a single standard or factor
Quantitation Calibration Blank with up to 20 standards
Quantitation Curve fit algorithms Quadratic, quadratic through zero, linear, linear through zero, interpolate
Kinetics Analysis Concentration, rate of change, initial and final absorbance/ %T
Spectrum Range 198 to 1000nm
Spectrum Scan interval 1, 2, 5 or 10nm
Spectrum Analysis Absorbance or transmittance, peak and valleys and area under the curve
Internal memory 10GB
External memory Limited by attached mass storage device
Outputs USB Type A x 2, USB Type B x 1, Ethernet connection (RJ45)
Size (w x d x h) 280 x 500 x 156mm
Weight 9kg
 

Availability: IN STOCK
SKU# 720601

Jenway Genova Bio UV/visible scanning spectrophotometer fitted with micro-cuvette holder, supplied with instruction manual and universal power supply with UK, EU and US power leads

• jenway Life Science Spectrophotometer
• Pre-programmed for DNA, RNA and protein analysis
• Compatible with ultra-micro, semi-micro, micro and macro cuvettes
• Scanning diode array technology
• Colour touchscreen navigation
• Small footprint and lightweight (< 3kg)
• Fast scan speed
• English, French, German, Italian and Spanish language options
• Multiple USB ports for data storage and printer connectivity
• 2-year warranty including xenon lamp

The Jenway Genova Bio is a simple, low cost, easy to use UV/visible spectrophotometer; dedicated for life science applications. The fast, responsive colour touchscreen and pre-programmed methods for the measurement of nucleic acid concentration and purity, protein assays and cell density, makes this spectrophotometer the ideal addition to any laboratory.

The Jeway Genova Bio utilises diode array technology to scan the entire wavelength range (198 to 800nm) in less than 3 seconds and the narrow spectral bandwidth of 3nm, makes it ideal to identify peaks for determining nucleic acid purity. 

The Jenway 1024 element diode array detector coupled with a flash xenon lamp results in a long life, robust spectrophotometer. Covered by a two-year warranty which includes the xenon lamp. 

The Nucleic Acids measurement mode can be used to quantify the concentration and purity of dsDNA, ssDNA, RNA and oligonucleotides; using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The concentration is calculated along with the corresponding ratios. At the touch of a button it is easy to check the purity of the nucleic acids. This is done by identifying distorted peaks in the purity scan between 200 and 350nm. This is especially useful for RNA samples where impurities maybe present at 230nm, but cannot be detected using the 260/ 280nm ratio measurement. 

The Proteins measurement mode can be used to calculate protein concentration by creating standard curves from protein assay kits. With pre-programmed methods for measuring Bradford, Lowry, Biuret and Bicinchoninic Acid (BCA) assays; up to 6 standards can be measured with 3 replicates of each standard to minimise any dilution errors. 

The Proteins measurement mode is also pre-programmed with the Direct UV and Warburg-Christian methods to determine protein purity. 

The Genova Bio has a pre-programmed method for measuring optical density of bacterial cultures such as E.Coli and yeast cells. This is ideal to measure cell growth before cell harvesting. 

As well as these pre-programmed methods this versatile spectrophotometer has measurement modes for simple photometrics, concentration, quantitation, spectrum scanning and kinetics. Enabling measurements to be performed at any selected wavelength between 198 to 800nm. 

Technical Specification

 

Wavelength Range 198 to 800nm
Wavelength Accuracy ± 2nm
Wavelength Repeatability ± 2nm
Spectral Bandwidth 3nm
Absorbance Range - 0.300 to 2.500A
Absorbance Accuracy ± 0.01A at 1.0A and 546nm
Absorbance Stability (A) ± 0.005A/h at 0.04A and 546nm
Noise ± 0.002A at 0.04A and ± 0.02A at 2.0A and 546nm
Stray Light at 340nm, %T < 1%T according to ANSI/ASTM E387- 72
Concentration Range ± 2500
Concentration Calibration Blank with a single standard or factor
Concentration Factor ± 1000
Concentration Standard ± 1000
Optical Density Factor ± 1000
Quantitation Range ± 2500
Quantitation Calibration Blank with up to 6 standards
Curve Fit Algorithms Linear and linear through zero
Kinetics Measurement Time 7 to 9999 seconds
Kinetics Number of wavelengths 3
Kinetics Calibration Blank with a factor
Kinetics Display Graphical and concentration
Kinetics Analysis Concentration
Spectrum Range 198 to 800nm
Spectrum Analysis Absorbance or % transmittance and up to 50 spectral analysis points
Beam Height 15mm
Light Source Xenon Lamp
Results/Method Memory Limited by attached USB memory stick
Removable Media USB
Outputs USB x 2
Supply voltage/frequency 100 - 240VAC at 50 to 60Hz
Power Supply 12V DC, 3.8A
Size (w x d x h) 212 x 422 x 120mm
Weight 2.8kg
Warranty 2 years on the instrument, including lamp

Availability: IN STOCK
SKU# 737 501

Model Genova Nano single beam, scanning, UV/visible range micro-volume spectrophotometer (198-1000nm) fitted with micro-volume accessory, supplied with single 10 x 10mm cuvette holder, micro-cuvette holder, universal power supply, 4GB USB memory stick, calibration standards and certificate and instruction manual.

The ability to measure very small volumes makes Genova Nano the perfect analysis tool for measuring the purity and concentration of biological samples. With such small volumes there is minimal sample loss - a significant advantage for DNA researchers and other labs where there is limited availability of sample. 

The Genova Nano is simple and quick to use, producing highly accurate and reproducible results in under than 6.5 seconds. It allows nucleic acid concentrations as low as 2ng/µl to be detected. Working with micro-volumes of 0.5µl to 5µl eliminates the need to make dilutions and use cuvettes. A small aliquot is simply placed on the stainless steel read head using a pipette. After measurement, wiping the read head surfaces with a lint-free cloth removes all traces of the sample, allowing fast changeover between samples and increased sample throughput.

Like the Genova Plus, the Genova Nano has pre-programmed methods for the measurement of ssDNA, dsDNA, RNA and oligonucleotide concentrations, as well as Bradford, Lowry, Biuret, BCA and Direct UV methods for protein analysis. In addition to dedicated life science measurement modes, this versatile instrument can also be used as a standard spectrophotometer with measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation and kinetics.

A large graphical display is built into the lid of the unit and the icon-driven software with soft-key navigation is intuitive and simple to use. The large internal memory can store over 300 methods, while methods and results can also be saved to a USB memory stick. Like the rest of the 73 series, the Genova Nano has an optional printer which fits into the top of the spectrophotometer, minimising the bench space required and enabling the production of instant results. The Genova Nano also offers the flexibility to use the full range of 73 series accessories. The instrument's 3-year warranty includes the xenon lamp.

  • 3 in 1 spectrophotometer
  • Ideal for DNA, RNA and Protein measurements
  • Only 0.5µl sample volume required
  • Easy and quick to clean
  • Detects DNA concentrations as low as 2ng/µl
  • Method and result saving to USB memory stick
  • 3 year warranty including Xenon lamp

Technical Specification

 

Parameter

Genova Nano

Wavelength Range

198 to 1000nm

Wavelength Accuracy

± 2nm

Spectral Bandwidth

5nm

Path Length

0.2 or 0.5mm (auto-ranging)

Absorbance Range

15 to 125A (10mm equivalent)

Absorbance Accuracy

± 2% at 260nm

Absorbance Precision

< 0.005A between 0 and 1A (at 260nm and 0.5mm)

Maximum Concentration

6,000 ng/µl (dsDNA) (at 0.2mm)

Detection Limit

2.0ng/µl (dsDNA) (at 0.5mm)

Measurement Time

< 6.5 seconds

Minimum sample Size

0.5µl (at 0.2mm),1.0µl (at 0.5mm)

Maximum sample size

5.0µl

DNA measurement modes

dsDNA, ssDNA, RNA, Oligonucleotides, 260/ 280, 260/ 230, Variable ratio

Protein measurement modes

Pierce 660, BCA, Bradford, Lowry, Biuret, Direct UV

Sample Pedestal Material

Quartz stainless steel

Light Source

Press to read Xenon lamp

Size (w x d x h), mm

275 x 400 x 220

Weight, kg

7.7

 


Availability: IN STOCK
SKU# 736 501

Model Genova Plus single beam, scanning, UV/visible range spectrophotometer (198-1000nm) fitted with micro-cuvette holder, supplied with single 10 x 10mm cuvette holder, universal power supply, 4GB USB memory stick, 100 disposable micro-cuvettes and instruction manual.

The new Genova Plus is a UV/visible spectrophotometer dedicated to life science analysis. This spectrophotometer allows the measurement of DNA concentrations and purity ratios using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The Genova Plus is pre-programmed with Bradford, Lowry, Biuret, BCA and Direct UV methods for protein analysis. The Genova Plus has an OD measurement mode enabling cell growth to be monitored by measuring absorbance at 600nm, 595nm or any other user selected wavelength. The purity scan across the entire wavelength range from 198 to 1000nm displays any distorted peaks enabling impurities to be easily identified. 

This life science spectrophotometer uses icon driven software and has an improved navigation system for easy and intuitive usability. As well as the dedicated life science measurement modes this instrument can also be used as a standard spectrophotometer with measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation and kinetics

• 5nm spectral bandwidth
• Absorbance range -0.3 to 2.5A
• Pre-programmed for DNA/RNA analysis
• Purity scan across entire wavelength range
• Pre-programmed methods for protein analysis 
• Standard spectrophotometer functions
• Press to read xenon lamp
• Icon driven software
• Small footprint
• Method and result saving to USB memory stick 
• 3 year warranty including xenon lamp

Technical Specification 

 


Wavelength Range

 

 

198 to 1000nm

Light source

Xenon lamp

Wavelength Resolution

1nm

Wavelength Accuracy

± 2nm

Wavelength Repeatibility

± 0.5nm

Spectral bandwidth

5nm

Photometric Transmittance

0 to 199.9%

Photometric Absorbance

- 0.300 to 2.500

Photometric Accuracy*

± 1%T, ± 0.01Abs at 1.000 Absorbance

Photometric Resolution

0.1%T, 0.001A

Concentration/Quantitation Range

0 to 9999

Concentation Calibration

Blank with a single standard or factor

Quantitation Calibration

Blank with up to 12 standards

Quantitation Curve fit algorithms

Quadratic, quadratic through zero, linear, linear through zero, interpolate

Kinetics Measurement time

2 to 9999 seconds

Kinetics Calibration

Blank with a single standard or factor

Kinetics Display

Graphical and concentration

Kinetics Analysis

Concentration, rate of change, initial and final absorbance/ %T

Spectrum/Purity Range

198 to 1000nm

Scan interval

selec table 1, 2 or 5nm

Spectrum/Purity Analysis

Absorbance or transmittance and peak and valleys

Multi-wavelength Data Points

Up to 4 wavelengths

Multi-wavelength Calculations

Sum, product, ratio and difference

DNA Measurement Modes

dsDNA, ssDNA, RNA, Oligonucleotides, 260/ 280, 260/ 230, Variable ratio

Multi-wavelength Plus Data Points

Up to 3 wavelengths plus optional reference wavelength

Multi-wavelength Plus Calculations

Concentration and ratio

Protein Measurement Modes

BCA, Bradford, Lowry, Biuret, Direct UV

OD 600 Range

0.00 E- 19 to 9.99 E+ 19

OD 600 Calibration

Blank with a single standard or factor

GLP Support

Current time and date, user ID, instrument lock and method lock

Method storage

312 (including pre-programmed methods)

Results memory

Limited by attached mass storage device

Removable media

USB (supplied)

Outputs

USB, Analogue, RS232, Integral printer

Size (w x d x h)

275 x 400 x 220mm

Weight

6kg

 

 