Water Purification Systems

Water Purification Systems

 

 Hydrolab Demineralizers - TECHNICAL Series

The TECHNICAL demineralizers are the widely used water purification systems fed by tap water, that retain 96-99% of dissolved organic and non-organic contamination, heavy metals and radioactive elements. Fully automated and unattended, equipped with a control and measurement system, monitoring all the stages of the water purification process. Obtained water matches the PN-EN ISO 3696:1999, ASTM, CLSI standards for the third class water quality.

Perfect for washers, analyzers, autoclaves, environmental chambers, water baths, HLP demineralizers, as well as, through developing a proper network, supplying several laboratory rooms and floors.

 Hydrolab Demineralizers - HLP Series

HLP demineralizers use tap water and fit every modern laboratory's requirements in areas of supplying with purified water for instrumental and analytical purposes. Conductivity of obtained water does not exceed 0,055 µS/cm, so it is applicable for PN-EN ISO 3696:1999, ASTM, CLSI, FP IX standards. Water may also be used for AAS, ICP/MS, IC, HPLC, GC instrumental analyses. In addition, our demineralizers are equipped with a microprocessor control and measurement system.

 Hydrolab Demineralizers - SPRING Series

SPRING demineralizers are devices fed by tap water, with a richer equipment and an advanced automatics. Same as the HLP demineralizers, SPRING systems produce water of a 0.055 µS/cm conductivity, fitting the PN-EN ISO 3696:1999, ASTM, CLSI, FP IX standards. These devices are dedicated for more demanding users by having an extended automatics, that allows the user to: monitor the disposable materials performance process, backup data, adjust alarm levels for the feed water, the water processed by the reverse osmosis, and the ultrapure water, control the automatic membrane rinsing, and the ultrapure water recirculation function. Systems also have safety protection functions for a comfortable device performance.

In SPRING systems, the demineralization process on ion exchange resisns is based on the SQF system (Slow Quick Flow), a new hydraulic solution allowing the filtrate recirculayion, keeping double demineralization. SQF results in a more efficient final demineralization by extended contact of a filtrate with the resin, while keeping a high product emission rate.

Disposable modules count in SPRING systems is reduced to two: A (initial filtration) and B (cleaning column operating in the SQF system), connected by quick connectors, so the replacement procedure may be performed easily by the user.

 Hydrolab Purifiers - ULTRA Series

Devices providing ultrapure water, that fits the PN-EN ISO 3696:1999 standard for the first purity class. System is fed by an external source of initially purified water that fits the requirements of II or III purity class, according to PN-EN ISO 3696:1999. Cleaning module is a fully automated and unattended system, equipped by default with an automatic diagnostic apparatus.

Water purification levels: deineralization and recirculation on a mixed ion exchange resin (TOC), UV lamp - 185/254nm, ultrafiltration, microfiltration (0,45/0,22 μm capsule).

 Hydrolab Demineralizers - R Series

R demineralizers devices, that combine features of two series: Spring and Cleaning into a one system, optimizing investment expenses/costs by eliminating common construction areas. These devices produce ultrapure water, that fitting the FP IX and PN-EN ISO 3696:1999 standards for first purity class. They are also equipped with an extended automatics, that allows the user to monitor disposable materials performance, data backup/archiving, individual adjustment of alarm levels for feed water parameters, water after reverse osmosis, and ultrapure water, along with controlling the function of automatic membrane modules rinsing. These systems also have several set s of protections included, for a comfortable system operation and user experience.

 Hydrolab Deionizers - BASIC Series

BASIC deionizers are devices of high demineralized water production efficiency. The quality of obtained water, depending on the tap water flow intensity, varies between 0,2-0,8 µS/cm. Fully automated and unattended maintenance-free devices are equipped with a microprocessor control and measurement system, which constantly monitors the water parameters. Purified water fits the PN-EN ISO 3696:1999, ASTM, CLSI standards for second purity class. BASIC deionizers are a perfect source of high quality water for washers, analyzers, autoclaves etc.

 Hydrolab Stations - PLUS Series

PLUS series stations are devices used in tap water softening, preparing it for further treatment by Hydrolab's HLP, TECHNICAL, SPRING demineralizers. They remove ions of calcium and magnesium from water.

A resin is treated by cyclic regenerations, so it can be replenished to its initial performance of water softening - the system is able to operate over many years.

 Hydrolab Demineralizers - INDUSTRIAL SYSTEMS: SPRING/TECHNICAL Series

INDUSTRIAL SYSTEMS - SPRING/TECHNICAL demineralizers, of an industrial efficiency of between 100 and 1000 dm3/h, allow to obtain water of a high pureness, matching the standards of PN-EN ISO 3696: 1999, ASTM, CLSI and FP IX.

These demineralizers may be used in an industry (pharmaceutical, food, cosmetics, electronics, etc.) as a central unit producing demineralized water, distributed through a network, feeding multiple laboratory rooms, floors or particular devices.

 

Use the search box to narrow the results of your search. RESET to clear your search. 

SKU# DB-010-0K

Deionizer, Efficiency: 100-200 L/h, Capacity: 10 L, 250 x 315 x 645 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Water delivery rate: 1-2 l/h
System efficiency: 100-200 dm
Column capacity: 10 dm3
Conductivity: 0,1 - 5 μS/cm

Standard:

Water purified in this device fits the PN-EN ISO 3696: 1999 standard for II and III purity class

Application:

Basic water for general laboratory purposes; for instrumental analyses: AAS, ICP/MS. May be used for preparations of mediums, buffer solutions, reagents. Can supply other laboratory devices: washers, analyzers, autoclaves, environmental chambers, cleaning demineralizers, etc.

Technical specification:

  • Device operates under tap water pressure.
  • Fed directly by tap water.
  • Water purification process stages: sediment filtration, integrated module (sediment-carbon), ionex demineralization: ion-exchange resin filtration (mixed bed - anionite and cationite).
  • Conductivity of obtained water (dependable on tap water flow): 0,1 - 5 µS/cm
  • Water intake point - II purity class (PN-EN ISO 3696:1999) with a demi water spout of a minimum 2 m reach.
  • Maintenance procedures may be performed by the user (easy disposable cartridges replacement).
  • Can be connected to an autoclave, a washer, a climate chamber etc.
  • Fed by cold water: 5-40 ºC
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Monitoring message/alarm preview.
  • Acid-proof stainless steel (inox) housing.


Monitoring functions

Equipped with a microprocessor control and measurement system:

  • LCD display screen 2x16 characters,
  • conductometer measuring conductivity and temperature of demineralized water (in µS/cm or MOhm),
  • displaying values compensated and uncompensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and activated carbon filters,
  • alarm informing about the necessity to replace the mixed bed,
  • service dates view,
  • installed RS 232 connector intended for the communication with a PC, allowing to adjust the service frequency and alarm levels
  • Manometer measuring feed water pressure.


Dimensions (width x depth x height): 250 x 315 x 645 mm
 
Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature: 5-40 0C
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3


Required connections:

  • cold tap water ½” lub ¾”
  • 230V socket 

Availability: IN STOCK
SKU# DB-015-0K

Deionizer, Efficiency: 150-300 L/h, Capacity: 15 L, 250 x 315 x 1105 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Water delivery rate: 1-2 l/h
System efficiency: 150-300 dm
Column capacity: 15 dm3
Conductivity: 0,1 - 5 μS/cm

Standard:

Water purified in this device fits the PN-EN ISO 3696: 1999 standard for II and III purity class

Application:

Basic water for general laboratory purposes; for instrumental analyses: AAS, ICP/MS. May be used for preparations of mediums, buffer solutions, reagents. Can supply other laboratory devices: washers, analyzers, autoclaves, environmental chambers, cleaning demineralizers, etc.

Technical specification:

  • Device operates under tap water pressure.
  • Fed directly by tap water.
  • Water purification process stages: sediment filtration, integrated module (sediment-carbon), ionex demineralization: ion-exchange resin filtration (mixed bed - anionite and cationite).
  • Conductivity of obtained water (dependable on tap water flow): 0,1 - 5 µS/cm
  • Water intake point - II purity class (PN-EN ISO 3696:1999) with a demi water spout of a minimum 2 m reach.
  • Maintenance procedures may be performed by the user (easy disposable cartridges replacement).
  • Can be connected to an autoclave, a washer, a climate chamber etc.
  • Fed by cold water: 5-40 ºC
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Monitoring message/alarm preview.
  • Acid-proof stainless steel (inox) housing.


Monitoring functions

Equipped with a microprocessor control and measurement system:

  • LCD display screen 2x16 characters,
  • conductometer measuring conductivity and temperature of demineralized water (in µS/cm or MOhm),
  • displaying values compensated and uncompensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and activated carbon filters,
  • alarm informing about the necessity to replace the mixed bed,
  • service dates view,
  • installed RS 232 connector intended for the communication with a PC, allowing to adjust the service frequency and alarm levels
  • Manometer measuring feed water pressure.


Dimensions (width x depth x height): 250 x 315 x 1105 mm
 
Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature: 5-40 0C
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3


Required connections:

  • cold tap water ½” lub ¾”
  • 230V socket 

Availability: IN STOCK
SKU# DB-002-0K

Deionizer, Efficiency: 20-40 L/h, Capacity: 2 L, 130 x 300 x 430 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Water delivery rate: 1-2 l/h
System efficiency: 20-40 dm3
Column capacity: 2 dm3
Conductivity: 0,1 - 5 μS/cm

Standard:

Water purified in this device fits the PN-EN ISO 3696: 1999 standard for II and III purity class

Application:

Basic water for general laboratory purposes; for instrumental analyses: AAS, ICP/MS. May be used for preparations of mediums, buffer solutions, reagents. Can supply other laboratory devices: washers, analyzers, autoclaves, environmental chambers, cleaning demineralizers, etc.

Technical specification:

  • Device operates under tap water pressure.
  • Fed directly by tap water.
  • Water purification process stages: sediment filtration, integrated module (sediment-carbon), ionex demineralization: ion-exchange resin filtration (mixed bed - anionite and cationite).
  • Conductivity of obtained water (dependable on tap water flow): 0,1 - 5 µS/cm
  • Water intake point - II purity class (PN-EN ISO 3696:1999) with a demi water spout of a minimum 2 m reach.
  • Maintenance procedures may be performed by the user (easy disposable cartridges replacement).
  • Can be connected to an autoclave, a washer, a climate chamber etc.
  • Fed by cold water: 5-40 ºC
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Monitoring message/alarm preview.
  • Acid-proof stainless steel (inox) housing.


Monitoring functions

Equipped with a microprocessor control and measurement system:

  • LCD display screen 2x16 characters,
  • conductometer measuring conductivity and temperature of demineralized water (in µS/cm or MOhm),
  • displaying values compensated and uncompensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and activated carbon filters,
  • alarm informing about the necessity to replace the mixed bed,
  • service dates view,
  • installed RS 232 connector intended for the communication with a PC, allowing to adjust the service frequency and alarm levels
  • Manometer measuring feed water pressure.


Dimensions (width x depth x height): 130 x 300 x 430 mm
 
Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa
  • Temperature: 5-40 0C
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3


Required connections:

  • cold tap water ½” lub ¾”
  • 230V socket 

Availability: IN STOCK
SKU# DB-025-0K

Deionizer, Efficiency: 250-500 L/h, Capacity: 25 L, 250 x 315 x 1105 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Water delivery rate: 1-2 l/h
System efficiency: 250-500 dm
Column capacity: 25 dm3
Conductivity: 0,1 - 5 μS/cm

Standard:

Water purified in this device fits the PN-EN ISO 3696: 1999 standard for II and III purity class

Application:

Basic water for general laboratory purposes; for instrumental analyses: AAS, ICP/MS. May be used for preparations of mediums, buffer solutions, reagents. Can supply other laboratory devices: washers, analyzers, autoclaves, environmental chambers, cleaning demineralizers, etc.

Technical specification:

  • Device operates under tap water pressure.
  • Fed directly by tap water.
  • Water purification process stages: sediment filtration, integrated module (sediment-carbon), ionex demineralization: ion-exchange resin filtration (mixed bed - anionite and cationite).
  • Conductivity of obtained water (dependable on tap water flow): 0,1 - 5 µS/cm
  • Water intake point - II purity class (PN-EN ISO 3696:1999) with a demi water spout of a minimum 2 m reach.
  • Maintenance procedures may be performed by the user (easy disposable cartridges replacement).
  • Can be connected to an autoclave, a washer, a climate chamber etc.
  • Fed by cold water: 5-40 ºC
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Monitoring message/alarm preview.
  • Acid-proof stainless steel (inox) housing.


Monitoring functions

Equipped with a microprocessor control and measurement system:

  • LCD display screen 2x16 characters,
  • conductometer measuring conductivity and temperature of demineralized water (in µS/cm or MOhm),
  • displaying values compensated and uncompensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and activated carbon filters,
  • alarm informing about the necessity to replace the mixed bed,
  • service dates view,
  • installed RS 232 connector intended for the communication with a PC, allowing to adjust the service frequency and alarm levels
  • Manometer measuring feed water pressure.


Dimensions (width x depth x height): 250 x 315 x 1305 mm
 
Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature: 5-40 0C
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3


Required connections:

  • cold tap water ½” lub ¾”
  • 230V socket 

Availability: IN STOCK
SKU# DB-005-0K

Deionizer, Efficiency: 50-100 L/h, Capacity: 5 L, 160 x 350 x 510 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Water delivery rate: 1-2 l/h
System efficiency: 50-100 dm
Column capacity: 5 dm3
Conductivity: 0,1 - 5 μS/cm

Standard:

Water purified in this device fits the PN-EN ISO 3696: 1999 standard for II and III purity class

Application:

Basic water for general laboratory purposes; for instrumental analyses: AAS, ICP/MS. May be used for preparations of mediums, buffer solutions, reagents. Can supply other laboratory devices: washers, analyzers, autoclaves, environmental chambers, cleaning demineralizers, etc.

Technical specification:

  • Device operates under tap water pressure.
  • Fed directly by tap water.
  • Water purification process stages: sediment filtration, integrated module (sediment-carbon), ionex demineralization: ion-exchange resin filtration (mixed bed - anionite and cationite).
  • Conductivity of obtained water (dependable on tap water flow): 0,1 - 5 µS/cm
  • Water intake point - II purity class (PN-EN ISO 3696:1999) with a demi water spout of a minimum 2 m reach.
  • Maintenance procedures may be performed by the user (easy disposable cartridges replacement).
  • Can be connected to an autoclave, a washer, a climate chamber etc.
  • Fed by cold water: 5-40 ºC
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Monitoring message/alarm preview.
  • Acid-proof stainless steel (inox) housing.


Monitoring functions

Equipped with a microprocessor control and measurement system:

  • LCD display screen 2x16 characters,
  • conductometer measuring conductivity and temperature of demineralized water (in µS/cm or MOhm),
  • displaying values compensated and uncompensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and activated carbon filters,
  • alarm informing about the necessity to replace the mixed bed,
  • service dates view,
  • installed RS 232 connector intended for the communication with a PC, allowing to adjust the service frequency and alarm levels
  • Manometer measuring feed water pressure.


Dimensions (width x depth x height): 160 x 350 x 510 mm
 
Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature: 5-40 0C
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3


Required connections:

  • cold tap water ½” lub ¾”
  • 230V socket 

Availability: IN STOCK
SKU# DH-0010-00

Demineralizer, Efficiency: 10 l/h, Purity Class: II, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP10 II class  DH-0010-00 
HLP10s I class  DH-0010-0S 
HLP10p  II class  DH-0010-0P 
HLP10sp  I class  DH-0010-SP 
HLP10UV  I class  DH-0010-UV 

 

General information

Supply: tap water
Efficiency: 10 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 10 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 10 - 12 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP10UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP10s, HLP10sp, HLP10UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP10p, HLP10sp, HLP10UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP10s, HLP10sp, HLP10UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0010-0P

Demineralizer, Efficiency: 10 l/h, Purity Class: II, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP10 II class  DH-0010-00 
HLP10s I class  DH-0010-0S 
HLP10p  II class  DH-0010-0P 
HLP10sp  I class  DH-0010-SP 
HLP10UV  I class  DH-0010-UV 

 

General information

Supply: tap water
Efficiency: 10 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 10 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 10 - 12 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP10UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP10s, HLP10sp, HLP10UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP10p, HLP10sp, HLP10UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP10s, HLP10sp, HLP10UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0010-0S

Demineralizer, Efficiency: 10 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP10 II class  DH-0010-00 
HLP10s I class  DH-0010-0S 
HLP10p  II class  DH-0010-0P 
HLP10sp  I class  DH-0010-SP 
HLP10UV  I class  DH-0010-UV 

 

General information

Supply: tap water
Efficiency: 10 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 10 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 10 - 12 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP10UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP10s, HLP10sp, HLP10UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP10p, HLP10sp, HLP10UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP10s, HLP10sp, HLP10UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0010-SP

Demineralizer, Efficiency: 10 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP10 II class  DH-0010-00 
HLP10s I class  DH-0010-0S 
HLP10p  II class  DH-0010-0P 
HLP10sp  I class  DH-0010-SP 
HLP10UV  I class  DH-0010-UV 

 

General information

Supply: tap water
Efficiency: 10 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 10 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 10 - 12 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP10UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP10s, HLP10sp, HLP10UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP10p, HLP10sp, HLP10UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP10s, HLP10sp, HLP10UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0010-UV

Demineralizer, Efficiency: 5 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP10 II class  DH-0010-00 
HLP10s I class  DH-0010-0S 
HLP10p  II class  DH-0010-0P 
HLP10sp  I class  DH-0010-SP 
HLP10UV  I class  DH-0010-UV 

 

General information

Supply: tap water
Efficiency: 10 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 10 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 10 - 12 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP10UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP10s, HLP10sp, HLP10UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP10p, HLP10sp, HLP10UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP10s, HLP10sp, HLP10UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0020-00

Demineralizer, Efficiency: 20 l/h, Purity Class: II, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP20 II class  DH-0020-00 
HLP20s I class  DH-0020-0S 
HLP20p  II class  DH-0020-0P 
HLP20sp  I class  DH-0020-SP 
HLP20UV  I class  DH-0020-UV 

 

General information

Supply: tap water
Efficiency: 20 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 20 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP20UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP20s, HLP20sp, HLP20UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP20p, HLP20sp, HLP20UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP20s, HLP20sp, HLP20UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0020-0P

Demineralizer, Efficiency: 20 l/h, Purity Class: II, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP20 II class  DH-0020-00 
HLP20s I class  DH-0020-0S 
HLP20p  II class  DH-0020-0P 
HLP20sp  I class  DH-0020-SP 
HLP20UV  I class  DH-0020-UV 

 

General information

Supply: tap water
Efficiency: 20 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 20 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP20UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP20s, HLP20sp, HLP20UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP20p, HLP20sp, HLP20UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP20s, HLP20sp, HLP20UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0020-0S

Demineralizer, Efficiency: 20 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP20 II class  DH-0020-00 
HLP20s I class  DH-0020-0S 
HLP20p  II class  DH-0020-0P 
HLP20sp  I class  DH-0020-SP 
HLP20UV  I class  DH-0020-UV 

 

General information

Supply: tap water
Efficiency: 20 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 20 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP20UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP20s, HLP20sp, HLP20UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP20p, HLP20sp, HLP20UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP20s, HLP20sp, HLP20UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0020-SP

Demineralizer, Efficiency: 20 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP20 II class  DH-0020-00 
HLP20s I class  DH-0020-0S 
HLP20p  II class  DH-0020-0P 
HLP20sp  I class  DH-0020-SP 
HLP20UV  I class  DH-0020-UV 

 

General information

Supply: tap water
Efficiency: 20 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 20 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP20UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP20s, HLP20sp, HLP20UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP20p, HLP20sp, HLP20UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP20s, HLP20sp, HLP20UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0020-UV

Demineralizer, Efficiency: 20 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP20 II class  DH-0020-00 
HLP20s I class  DH-0020-0S 
HLP20p  II class  DH-0020-0P 
HLP20sp  I class  DH-0020-SP 
HLP20UV  I class  DH-0020-UV 

 

General information

Supply: tap water
Efficiency: 20 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 20 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP20UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP20s, HLP20sp, HLP20UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP20p, HLP20sp, HLP20UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP20s, HLP20sp, HLP20UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0030-00

Demineralizer, Efficiency: 30 l/h, Purity Class: II, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP30 II class  DH-0030-00 
HLP30s I class  DH-0030-0S 
HLP30p  II class  DH-0030-0P 
HLP30sp  I class  DH-0030-SP 
HLP30UV  I class  DH-0030-UV 

 

General information

Supply: tap water
Efficiency: 30 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 30 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP30UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP30s, HLP30sp, HLP30UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP30p, HLP30sp, HLP30UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP30s, HLP30sp, HLP30UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

 


Availability: IN STOCK
SKU# DH-0030-0P

Demineralizer, Efficiency: 30 l/h, Purity Class: II, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP30 II class  DH-0030-00 
HLP30s I class  DH-0030-0S 
HLP30p  II class  DH-0030-0P 
HLP30sp  I class  DH-0030-SP 
HLP30UV  I class  DH-0030-UV 

 

General information

Supply: tap water
Efficiency: 30 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 30 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP30UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP30s, HLP30sp, HLP30UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP30p, HLP30sp, HLP30UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP30s, HLP30sp, HLP30UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain

Availability: IN STOCK
SKU# DH-0030-0S

Demineralizer, Efficiency: 30 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP30 II class  DH-0030-00 
HLP30s I class  DH-0030-0S 
HLP30p  II class  DH-0030-0P 
HLP30sp  I class  DH-0030-SP 
HLP30UV  I class  DH-0030-UV 

 

General information

Supply: tap water
Efficiency: 30 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 30 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP30UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP30s, HLP30sp, HLP30UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP30p, HLP30sp, HLP30UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP30s, HLP30sp, HLP30UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain

Availability: IN STOCK
SKU# DH-0030-SP

Demineralizer, Efficiency: 30 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP30 II class  DH-0030-00 
HLP30s I class  DH-0030-0S 
HLP30p  II class  DH-0030-0P 
HLP30sp  I class  DH-0030-SP 
HLP30UV  I class  DH-0030-UV 

 

General information

Supply: tap water
Efficiency: 30 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 30 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP30UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP30s, HLP30sp, HLP30UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP30p, HLP30sp, HLP30UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP30s, HLP30sp, HLP30UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain

Availability: IN STOCK
SKU# DH-0030-UV

Demineralizer, Efficiency: 30 l/h, Purity Class: I, 230 x 450 x 580 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP30 II class  DH-0030-00 
HLP30s I class  DH-0030-0S 
HLP30p  II class  DH-0030-0P 
HLP30sp  I class  DH-0030-SP 
HLP30UV  I class  DH-0030-UV 

 

General information

Supply: tap water
Efficiency: 30 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 5ppb*
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in a HLP 20 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,2 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 30 dm3/h.
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP30UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP30s, HLP30sp, HLP30UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP30p, HLP30sp, HLP30UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP30s, HLP30sp, HLP30UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 450 x 580 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain

Availability: IN STOCK
SKU# DH-0005-00

Demineralizer, Efficiency: 5 l/h, Purity Class: II, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP5 II class  DH-0005-00 
HLP5s I class  DH-0005-0S 
HLP5p  II class  DH-0005-0P 
HLP5sp  I class  DH-0005-SP 
HLP5UV  I class  DH-0005-UV 

 

General information

Supply: tap water
Efficiency: 5 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

* Device equipped with a 0,2 μm microfiltration capsule

Standard:

Water purified in a HLP 5 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 5 - 7 dm3/h (daily: 120-168 dm3).
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP5UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP5s, HLP5sp, HLP5UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP5p, HLP5sp, HLP5UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP5s, HLP5sp, HLP5UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dm3 for purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

 


Availability: IN STOCK
SKU# DH-0005-0P

Demineralizer, Efficiency: 5 l/h, Purity Class: II, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP5 II class  DH-0005-00 
HLP5s  I class  DH-0005-0S 
HLP5p  II class  DH-0005-0P 
HLP5sp  I class  DH-0005-SP 
HLP5UV  I class  DH-0005-UV 

 

General information

Supply: tap water
Efficiency: 5 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

* Device equipped with a 0,2 μm microfiltration capsule

Standard:

Water purified in a HLP 5 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 5 - 7 dm3/h (daily: 120-168 dm3).
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP5UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP5s, HLP5sp, HLP5UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP5p, HLP5sp, HLP5UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP5s, HLP5sp, HLP5UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0005-0S

Demineralizer, Efficiency: 5 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

  

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP5 II class  DH-0005-00 
HLP5s  I class  DH-0005-0S 
HLP5p  II class  DH-0005-0P 
HLP5sp  I class  DH-0005-SP 
HLP5UV  I class  DH-0005-UV 

 

General information

Supply: tap water
Efficiency: 5 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

* Device equipped with a 0,2 μm microfiltration capsule

Standard:

Water purified in a HLP 5 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 5 - 7 dm3/h (daily: 120-168 dm3).
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP5UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP5s, HLP5sp, HLP5UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP5p, HLP5sp, HLP5UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP5s, HLP5sp, HLP5UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0005-SP

Demineralizer, Efficiency: 5 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP5 II class  DH-0005-00 
HLP5s  I class  DH-0005-0S 
HLP5p  II class  DH-0005-0P 
HLP5sp  I class  DH-0005-SP 
HLP5UV  I class  DH-0005-UV 

 

General information

Supply: tap water
Efficiency: 5 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

* Device equipped with a 0,2 μm microfiltration capsule

Standard:

Water purified in a HLP 5 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 5 - 7 dm3/h (daily: 120-168 dm3).
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP5UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP5s, HLP5sp, HLP5UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP5p, HLP5sp, HLP5UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP5s, HLP5sp, HLP5UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0005-UV

Demineralizer, Efficiency: 5 l/h, Purity Class: I, 230 x 360 x 520 mm, microprocessor control and measurement system, 230V/50Hz

 

Models Microfiltration  0,2μm Pump increasing pressure Lamp 254 nm

Standard

PN-EN 3696: 1999

SKU No.
HLP5 II class  DH-0005-00 
HLP5s  I class  DH-0005-0S 
HLP5p  II class  DH-0005-0P 
HLP5sp  I class  DH-0005-SP 
HLP5UV  I class  DH-0005-UV 

 

General information

Supply: tap water
Efficiency: 5 l/h
Water delivery rate: 1-2 l/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb 
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

* Device equipped with a 0,2 μm microfiltration capsule

Standard:

Water purified in a HLP 5 device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 μm

Technical specification:

  • Operates under the tap water pressure.
  • Water purification process stages: sediment prefilter 5µm, integrated module (sediment-carbon-softening), reverse osmosis, initial demineralization on the mixed ion-exchange resin, repeated demineralization on the mixed ion-exchange resin
  • System efficiency: 5 - 7 dm3/h (daily: 120-168 dm3).
  • Demineralized water conductivity < 0,06 µS/cm.
  • UV lamp – 254 nm (model: HLP5UV)
  • Microfiltration cascade capsule 0,45/0,22 μm (models: HLP5s, HLP5sp, HLP5UV)

Unattended and Automated System Operation

  • Equipped with a pump increasing feed water pressure (model: HLP5p, HLP5sp, HLP5UV)
  • Mobile water collection point - second purity class (PN-EN ISO 3696:1999), with a demi water nozzle (min. 2 m reach)
  • Additional ultrapure water collection point - first purity class (PN-EN ISO 3696:1999) (with an optional microfiltration capsule 0,2μm - model: HLP5s, HLP5sp, HLP5UV).
  • Optional installation of an additional general purpose water collection point - third purity class (PN-EN ISO 3696: 1999, intended for laboratory glass cleaning, washer supply etc.)
  • Mobile, adjustable inox arm holding water collection points – available adjustment ranges: up/down, front/back, left/right.
  • Pressure tank 10 dmfor purified water storage. (a larger tank is optional)
  • System autoshutdown when the tank is full.
  • Optional connection to a washer, an autoclave etc.
  • Service operations may be performed by the user (easy disposable materials replacement).
  • UV lamp lifetime - 8500 hours (model: HLPUV)
  • Maximum working pressure: 1 MPa.
  • Should be fed by cold water: 5-40°C
  • Power supply: 230V/50Hz.
  • Can be installed by the user.
  • Acid-proof stainless steel (inox) housing.


Functions monitoring system performance:

The device is equipped with a microprocessor control and measurement, that includes:

  • LCD display screen 2x16 characters,
  • conductometer measuring purified water pressure (in µS/cm or MOhm)
  • displaying values compensated thermally,
  • clock displaying date and time,
  • alarm informing about the necessity to replace the mechanical and carbon filters,
  • alarm informing about the necessity to replace the ion exchange resins,
  • alarm informing about the necessity to replace the UV lamp,
  • alarm informing about the necessity to replace the microfiltration capsule,
  • service dates display,
  • RS 232 connector for the communication with a PC,
  • personalization of the service dates and alarm levels directly from the device's keyboard.
  • Manometer displaying date and time

Functions protecting the device:

Pump shutdown when:

  • feed water pressure is too low (lack of feed water) – low pressure sensor,
  • the tank is full – high pressure sensor.


Dimensions (width x length x height): 230 x 360 x 520 mm

Feed water parameters:

  • Conductivity < 1200 µS/cm
  • Pressure > 0,35 MPa 
  • Temperature : 5-40 oC
  • Hardness < 250 mg CaCO3/dm3
  • Fe < 0,2 mg/dm3

Installation point connections:

  • cold tap water connection ½” lub ¾”
  • 230V power supply socket
  • drain 

Availability: IN STOCK
SKU# DH-0004-00

Demineralizer, Efficiency: 4 l/h, Purity Class: II, 200 x 360 x 420 mm, microprocessor control and measurement system, 230V/50Hz

 

General information

Supply: tap water
Efficiency: 4 dm3/h
Water delivery rate: 1-2 I/min
Conductivity < 0,06 µS/cm
Na+, SO42-, Cl-, Br-, N02-, NO3-, P043- < 0.5 ppb
Fe, Zn, Cu, Cr, Mn < 0.1 ppb
TOC < 30ppb
Bacteria < 1 cfu/ml *
Particles > 0,2μm < 1/ml*

Standard:

Water purified in this device fits the PN-EN ISO 3696:1999 standard for I*, II, III purity class, and microbiological/physicochemical FP IX requirements for purified production water*.

Application:

Instrumental analyses: UV-VIS, AAS, ICP/MS, IC, HPLC*, GC*, bacteria cultures*, biochemical analyses*, preparation of buffer solutions, reagents and mediums, rinsing and washing.

* Device equipped with a UV lamp and a microfiltration capsule 0,22 &m